It gets wet it rots and it attracts termites.
Ground level wood siding.
Add felt if needed before nailing the new wood on and prime the new wood on all four sides before installing it.
You could also remove the lowest part of the siding put on a waterproof membrane and replace it with siding that isn t damaged by water like cement board with parging stucco or corrugated metal.
If the shingle already has flashing on it the kickout flashing has to slip beneath it and you ll have to loosen or remove siding to do this.
Inexpensive and simple to do sealing your siding only requires a little time to locate the cracks.
No wood comes anywhere close to the ground.
When it is higher from the ground splashing water onto the wood is minimized.
I am replacing old vinyl siding with pine board and batten.
The bottom 3 boards had already been replaced all the way around at around 10 years because the idiot builder thought that it would look prettier with siding to the ground.
Wood siding stucco vinyl brick all siding should ideally have at least 6 to 8 inches clearance above the ground.
By sealing gaps in your walls and siding you can successfully secure your home from outdoor pests.
Siding replacement height from ground building code standards better than building code installation michael slater is putting new wood siding on his house in st.
Plytanium t1 11 natural rough sawn syp plywood panel siding common.
2306 8 wood and earth separation.
0 563 in x 47 875 in x 95 875 in item 12957 model na.
Wood siding should be 4 or so from the ground whether that be soil or solid surface.
For comparison my 1998 home is in need of new siding because of the sawdust weyerhaueser siding.
Holes occur over time when seals crack around plumbing fixtures on your siding allowing mice entrance into your home.
Here s what he said.
Install the kickout flashing underneath the first shingle photo 1.
Even where permitted by code such as where wood materials are all preservative treated placing wood siding and walls below ground level or close to ground may nevertheless invite wood destroying insects into the structure if siding sheathing insulation or other materials lack adequate clearance.
But don t dig it so low that the ground is pitched toward the garage.
How far off the ground level should i.
If the adjacent ground is concrete such as part of a patio or a sidewalk it still requires the same clearance as bare earth.
Any clearance is better than none.
This is what happens when wood siding is too close to the ground.
0 594 in x 48 in x 96 in.
Six inches would not be too far.